|
- User's Guide.
Electronics of metal detectors use different
principles, some of them have proved in practice to be more successful and
reliable than others. Unquestionably, the most popular, the most effective and
affordable metal detectors function on the principles of induction balance and
pulse induction. This makes the problem of ground neutralization crucial. On
“heavy” soils and when the induction balance detectors cannot be used, the pulse
induction detectors become preferable. Their very low frequency makes them
efficient even on highly mineralized and salty ground. This explains why almost
all well-known manufacturers have pulse induction models. With this type of
detectors, the search coil is not part of the resonance circuit, but a
self-contained generator starts the pulse signal. The parameter to be analyzed
is the transition time /the position of the pulse front/.
Pulse induction detectors are very efficient at profound search as they allow
scanning with large square heads /frames/ of size from 1m x 1m to 2m x 2m and
even larger. At the same time, the main disadvantage of this technology is its
low capability to distinguish ferrous from non-ferrous metals. This narrows
otherwise the entire hegemony of pulse induction detectors. The experience with
these teaches that they alone are difficult to use, especially when they are
equipped with large loops or frames. Pinpointing of small metal objects is hard
and their identification unreliable. The two technologies advantages and
disadvantages complement one another and they are almost always used together
especially when a pulse induction detector with a large search frame is needed.
First you scan with the induction balance detector to eliminate tiny and near
the surface objects and then the pulse induction detector with its deep search
frame will identify bigger objects deeper in the ground. Moreover, very deep
small and large metal objects can be detected with ease. The only thing that has
to be done is to switch between the two technologies and change the search heads
in turn.
GRIZZLY TWINS combines the two technologies and provides detection on any soil
and up to 3 m in depth. GRIZZLY TWINS is compact, highly sensitive, stable and
easy to use. The detector and its accessories come in a sturdy and convenient
carry bag which makes its use and transportation simple and handy.
The induction balance detector has its control knobs and switches positioned in
the left on the control panel, the right portion of which is for the pulse
induction detector digital display and its control buttons.
The selection of the mode is done with a button in the middle of the panel. It
is this button that provides you to use only the advantages of these metal
detection technologies.

Basic Pack 1
Search head for PI
38 cm;
Search head for IB oval DD22x32 cm;
Camouflage rucksack;
Telescopic handle with a carbon bar;
Control unit;
Stereo headphones with adapter and independent left and right active volume
control;
Charging unit: 220 and 12V for a car lighter;
Control unit case – made of high-quality waterproof and heat-resistant isolation
material;
Optional: Search frame 1m x 1m. It can be ordered in addition to the basic pack
or as a replace of the search head for PI 33cm or 38 cm – this pack is called:
Basic Pack 2
Search head for PI 1m x 1m; - IF YOU WANT TO
ORDER THIS PACK 2 FOR THE SAME PRICE, PLEASE CLICK DOWN.
Search head for IB oval DD22x32 cm;
Camouflage rucksack;
Telescopic handle with a carbon bar;
Control unit;
Stereo headphones with adapter and independent left and right active volume
control;
Charging unit: 220 and 12V for a car lighter;
Control unit case – made of high-quality waterproof and heat-resistant isolation
material;


HOW TO WORK
IN PULSE INDUCTION
MODULE?
Grizzly Twins Digital PI
was designed by a new technology in which the signal 'back integration' used
with this type of instruments (Pulse Induction) was replaced by a contemporary
analog-to-digital converter and a microprocessor.
The POWER switch is normally in middle position, the detector being
turned off. Turn the switch to the left (towards IB) and there will be a slight
click, which means that the instrument is working in IB mode. To disable the
mode leave the switch in middle position and turn the POWER switch right
(towards PI), you will hear a click that means the PI mode is enabled. To turn
off simply leave the POWER switch in middle position.
Turn the POWER switch right (towards PI) and you will hear a quiet click,
the instrument is now working in PI mode. To exit the mode, leave the POWER
switch in middle position.

Control functions
The front panel has 4 buttons on it with the following functions:
 On
pressing one of these buttons you decrease or increase the silent threshold.
ZERO
or reset. The button also confirms each change of a parameter in the menu.
This
button is to enter the menu as well as to cancel an adjustment.
Information on the display:


The first line shows the strength of the signal.
The second line gives the following values.
Ò õõ
V x
xx.x
V
T xx–
Threshold
–
is the Threshold which can be directly adjusted by the left and right arrows
without having to enter the menu.
 
V
x
- Volume
xx.x
V
–
U batt
–
Shows the battery voltage
Menu
Press the MENU button
to
enter the menu and change the setting. Use the left and right arrows
 to
move up and down within the menu items. To enter a submenu, press the ENTER/ZERO
buttonå.

-
Volume
-
Light
-
U min of batt
-
Guard interval
-
Ground adjust
-
Volume raise
Description:

Volume
– Sound from a minimum level of 0 to a maximum level of 7
Light
– Backlight – By default the setting is ON, but this menu will allow you to turn
it off.

U min of
batt -
The minimum voltage at which the instrument will alarm a weak battery. The
minimum user's adjustment step is100 mV.

Guard
interval –
The coil settings
-auto
– At each start of the instrument it will adjust to the installed search head
automatically.

-last
-
In case you will not use a different search head and you will scan with the head
the instrument has already been set to work with, you need not waste time and
wait for the detector to adjust to it, at the next start the last settings will
be applied.
-You
can manually change the setting for the Ground interval from 2 to 80;
this parameter can be used as an additional function to eliminate the signals
from the ground if such are present and cannot be neutralized with the
Ground adjust function.
If the instrument detects signals from the ground at setting of 20, for example,
a lower number will cause unstable work and false signals but higher sensitivity
at the same time. The greater this number is, the less sensitive but more stable
the instrument will be. In cases when the ground signals cannot be eliminated by
adjusting the three parameters of Ground adjust, this number has
to be manually increased.
Ground adjust
–
This function has three software approaches to neutralize the
ground at different scan modes.
-off(static)
-
Ground balance is turned off or this is also called static mode or 'if there
is an object, there is a signal'.
-adaptive
-
Adaptive processing of the signal - 1st dynamic mode.
*
When holding the search head still above a target the signal dies away, the head
must be in motion so that the detector produces a sound.
-fixing
-
fixed software Ground balance adjustment - 2nd dynamic mode.

*
This mode is a combination of the previous two modes with the search head being
in motion all the time. Keep in mind that this mode is slower, i.e. if you reach
out a coin towards the search head in adaptive mode, then take it
away and back again, the instrument will detect the coin, while in fixing
mode and especially when the search speed is higher, it is likely that the
target does not produce a sound.

Volume
raise
-1/32, 1/16/ 1/8, ¼, ½ , 1
– This parameter is used to slow down the increase of the sound level at the
beginning of the scale. It improves the stable work of the scheme at lower
threshold. This parameter is reciprocal to the instrument sensitivity. So it is
the most sensitive at 1/32 and when the silent threshold is low, it ought to be
closer to 1.

HOW TO WORK
IN
IB
MODE
Use the POWER switch to turn on/off the instrument as well as to switch between
the IB and PI mode. Normally the switch is in middle position, then, the
instrument is off. Turn the POWER switch to the left (towards IB) and you will
hear a low click, this means the detector is started in IB mode.
Control knobs
·
Discrimination mode switch:
The switch has two positions: 1 – Left position (GEB), in this mode the
discrimination is off, i.e. the instrument detects all metals and produces a
consistent sound; 2 - Right position (DISK), when the instrument
discriminates the metals, .i.e. at detection of non-ferrous metal targets it
gives out a consistent sound versus broken and inconsistent signals when
detected ferrous objects.

·
VOLUME
knob: Use this control to increase or decrease the signal out of the speaker;
·
TUNE
knob (for adjustment of the critical signal). The TUNE knob controls the
silent threshold. Turn the knob right and you will hear a slowly increasing
signal, with the help of the knob set this signal very weak. This weak signal is
called critical signal (silent threshold). The instrument is the most sensitive
when it works at the signal threshold setting.
·
DISK
knob (to increase or decrease the discrimination level). It controls the
instrument's level of discrimination the discrimination being higher at greater
numbers at the DISK knob, namely the instrument will produce a consistent
signal (Discrimination ON) when it detects purer non-ferrous metals and its
sound will be broken and inconsistent when the detected object is iron.
·
GEB
knob (to control mineralized ground detection): Turn the knob left or right to
neutralize the signals from the ground, i.e. this control allows to ground
balance the instrument in IB mode.

THIS IS BASIC PACK 1, WIHTOUT SEARCH FRAME
1M.X1M.
TO ORDER THE SET WITH IT, BUT WITHOUT 38CM.
SEARCH COIL PLEASE CHOOCE FROM THE FOLLOWING MENU - BASIC PACK 2 -
THE SAME PRICE
IF YOU WANT TO ORDER BASIC PACK 1 WITH
ADDITIONAL 1M.X1M. SEARCH FRAME PLEASE ADD FROM THE MENU BELOW.
| Available Options: |
| Additional search coil: |
|
| BASIC PACK: |
|
|